{"product_id":"vk-700-advanced-multi-threat-filter-cartridge-comprehensive-protection-against-gases-vapors-aerosols-cbrn-agents","title":"VK-700 Advanced Multi-Threat Filter Cartridge: Comprehensive Protection Against Gases, Vapors, Aerosols \u0026 CBRN Agents","description":"\u003cp\u003e\u003cem\u003e\u003cspan\u003e\u003cstrong\u003eEngineered for Critical Respiratory Defense in Extreme Environments\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eWhen facing complex airborne hazards—from industrial chemicals to biological threats—compromised protection is unacceptable. The VK-700 Advanced Combined Filter Cartridge delivers certified, multi-threat respiratory defense, meeting the rigorous EN 14387:2004+A1:2008 standard. Designed for professionals requiring uncompromising safety, it integrates broad-spectrum filtration with ergonomic engineering.\u003c\/p\u003e\n\u003ch2\u003eUnmatched Protection Spectrum: Safeguarding Against Diverse Airborne Threats\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eToxic Gases \u0026amp; Vapors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOrganic solvents, acid gases (Chlorine, Hydrogen Cyanide), Ammonia,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMercury vapors\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNitrogen Oxides (NO\/NO₂)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCarbon Monoxide (CO)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePhosgene (SX)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticulates \u0026amp; Aerosols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid\/liquid aerosols, radioactive particles,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003easbestos fibers\u003c\/strong\u003e, hydroxides, phosphoric acid derivatives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCBRN \u0026amp; Riot Control Agents:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChemical, Biological, Radiological, Nuclear (CBRN) threats and tear gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features \u0026amp; Technical Superiority: Performance You Can Trust\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified Broad-Spectrum Filtration (EN 14387:2004+A1:2008):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndependently validated performance against specific gases and particulates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized Breathability \u0026amp; Comfort:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLow breathing resistance ensures stamina during extended operations (≤190 Pa @ 30 L\/min; ≤870 Pa @ 95 L\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Mask Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly integrates with full-face respirators featuring:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 148-1 (Rd 40×1\/7\")\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThread (\u003cstrong\u003eOrder Code: 1640\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGOST 8762-75 (OZ 40×4 mm)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThread (\u003cstrong\u003eOrder Code: 2640\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact, Lightweight Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDimensions: Ø 110 mm × H 95 mm. Weight: 450 g ± 1.5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Shelf Life \u0026amp; Durable Storage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintains efficacy for 10 years when stored correctly (−5 °C to +30 °C, \u0026lt;80% RH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Particulate Filtration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaximum 0.05% penetration for aerosols\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry-Leading Mercury Vapor Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for 100 hours at 0.1 mg\/m³; tested breakthrough time \u0026gt;170 h under the same concentration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"scrollable-wrapper\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Type\u003c\/td\u003e\n\u003ctd\u003eA2B2E2K2HgNOCO20P3 (Combined Filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEN 14387:2004+A1:2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm Diameter, 95 mm Height (incl. thread)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e450 g ± 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf Life\u003c\/td\u003e\n\u003ctd\u003e10 years (proper storage required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreathing Resistance\u003c\/td\u003e\n\u003ctd\u003e≤190 Pa (@ 30 L\/min), ≤870 Pa (@ 95 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−5 °C to +30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Options \/ Order Codes\u003c\/td\u003e\n\u003ctd\u003eEN 148-1 (Rd 40×1\/7\") —\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1640\u003c\/strong\u003e; GOST 8762-75 (OZ 40×4 mm) —\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2640\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePerformance Validation (EN 14387:2004+A1:2008)\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eTesting conditions: 30 L\/min flow unless noted; breakthrough concentration as specified; test concentrations shown in both ppm and mg\/L.\u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"scrollable-wrapper\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eTest Gas\u003c\/th\u003e\n\u003cth\u003eDynamic Adsorption Capacity (g)\u003c\/th\u003e\n\u003cth\u003eBreakthrough Concentration\u003c\/th\u003e\n\u003cth\u003eBreakthrough Time (min)\u003c\/th\u003e\n\u003cth\u003eTest Gas Concentration\u003c\/th\u003e\n\u003cth\u003eFlow Rate (L\/min)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA2\u003c\/td\u003e\n\u003ctd\u003eCyclohexane (C₆H₁₂)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;40\u003c\/td\u003e\n\u003ctd\u003e5,000 ppm (17.5 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl₂)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;40\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (15 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;40\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (7.1 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH₃)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;40\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (13.3 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMercury vapor (Hg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 h\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u0026gt;170 h\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.1 mg\/m³\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO\u003c\/td\u003e\n\u003ctd\u003eNitric oxide (NO)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e0.25%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;20\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (3.1 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO₂\u003c\/td\u003e\n\u003ctd\u003eNitrogen dioxide (NO₂)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e0.25%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;20\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (4.8 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;20\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (20.24 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSX\u003c\/td\u003e\n\u003ctd\u003ePhosgene (COCl₂)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e0.5%\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;20\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm (12.144 mg\/L)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCritical Applications: Where the VK-700 Excels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Worksites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChemical processing, painting,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003easbestos abatement\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Materials (HazMat) Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpill control, decontamination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirefighting \u0026amp; Smoke Inhalation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCO and combustion product protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisaster Relief \u0026amp; CBRN Preparedness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChemical incident response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Services:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRiot control (tear gas) scenarios\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eThe VK-700 Advantage: Beyond Standard Smoke\/CO Filters\u003c\/h2\u003e\n\u003cp\u003eWhile filters like the VK-530 focus primarily on smoke and carbon monoxide, the VK-700 provides comprehensive, multi-threat protection. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA2B2E2K2HgNOCO20P3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eclassification signifies defense against a wider array of gases, vapors, mercury, and particulates essential for unpredictable hazardous environments.\u003c\/p\u003e\n\u003ch2\u003eEssential Safety Information \u0026amp; Usage\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility is Crucial:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMatch thread type (EN 148-1 or GOST 8762-75) to your full-face mask\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Life During Use:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVaries based on contaminant concentration and breathing rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShelf Life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10-year lifespan applies only to unused filters stored at −5 °C to +30 °C and \u0026lt;80% RH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the VK-700 compare to other combined filters?\u003c\/strong\u003e\u003cbr\u003eThe VK-700 offers exceptional breadth of protection (A2B2E2K2HgNOCO20P3), industry-leading 100-hour Hg rating (tested \u0026gt;170 h breakthrough), certified low breathing resistance, and 10-year shelf life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the VK-700 effective against asbestos and radioactive particles?\u003c\/strong\u003e\u003cbr\u003eYes. Its P3 particulate component is highly efficient (≤0.05% penetration) against solid aerosols like asbestos fibers and radioactive dust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know if the VK-700 fits my respirator?\u003c\/strong\u003e\u003cbr\u003eIdentify your mask’s thread standard (marked or in manual). Choose\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOrder Code 1640\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor EN 148-1 or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2640\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor GOST 8762-75.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the Mercury (Hg) protection rated in hours?\u003c\/strong\u003e\u003cbr\u003eMercury vapor testing (EN 14387) uses continuous exposure at 0.1 mg\/m³. The “100 hours” indicates minimum effective protection; tested breakthrough exceeded 170 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I rely solely on the 10-year shelf life?\u003c\/strong\u003e\u003cbr\u003eThe 10-year shelf life requires strict storage conditions. Once opened or used, monitor for end-of-service-life indicators during use.\u003c\/p\u003e\n\u003ch2\u003eChoose Uncompromising Respiratory Safety\u003c\/h2\u003e\n\u003cp\u003eThe VK-700 Advanced Combined Filter Cartridge represents certified, broad-spectrum respiratory protection for demanding airborne hazards. Protect your most vital asset – your ability to breathe safely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelect Your Thread Standard \u0026amp; Order Today:\u003c\/strong\u003e\u003cbr\u003eEN 148-1 (Rd 40×1\/7\"):\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOrder Code 1640\u003c\/strong\u003e\u003cbr\u003eGOST 8762-75 (OZ 40×4 mm):\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOrder Code 2640\u003c\/strong\u003e\u003c\/p\u003e","brand":"MIRA Safety","offers":[{"title":"Default Title","offer_id":48249608372382,"sku":null,"price":74.93,"currency_code":"SHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0458\/1582\/4542\/files\/VK-700-main.webp?v=1788909436","url":"https:\/\/alpenglowsupplyak.com\/products\/vk-700-advanced-multi-threat-filter-cartridge-comprehensive-protection-against-gases-vapors-aerosols-cbrn-agents","provider":"Alpenglow Readiness Supply","version":"1.0","type":"link"}